YQ&YZ&YC Series Rubber Sheath Flexible Cable
$666.00
Model
BXLF
1111
Basic info
Brand Wone
Model NO. Rubber sheath flexible calbe for communication 300V/750V
Rated voltage 17kV
Rated insulation voltage 16
type Distribution
Series YQ&YZ&YC
Product Detail

Executive standard

GB/T5013-2008 JB8735-1998 Q/YL10-2008

usage

This product is suitabel for rated ac voltage 450/750V or below domestic appliaces, power-operated tools and various portable electric equipments.

Exploitation conditions

a.Rated voltage Uo / U: 

    YQ, YQW type 300/300V, 

    YZ, 60245IEC 53 (YZ)-type 300/500V

    YZW, 60245IEC 57 (YZW) type 300/500V

    YC, YCW, 60245IEC 66 (YCW) type 450/750V

b.Long time allow working temperature of wire core is not more than 65 .

c.W model cable has the property of durability and suitable for cutdoor touching of greasy dirt.

model name and usage

通用橡皮电缆用途.png

Size,weight and technological date

300/300V YQ,YQW  light model

300V YQ YQW.png

300/500V 60245IEC53(YZ),YZ;60245IEC 57(YZW),YZW300 500V YZ YZW.png

450/750V 60245IEC 66(YCW),YCW;YC450 750V YC YCW.png

Current-carrying energy

General purpose rubber sheathed flexible cable carrying capacity通用橡皮电缆载流表.png

Exchange coefficient of rate of different surrounding temperature通用橡皮电缆载流表温度系数.png


Q: What is the difference between YQ, YZ and YC cables? 

A: YQ cable is a light rubber sheath flexible cable, it is relatively light, suitable for light mobile electrical equipment; YZ cable is a medium-sized rubber sheath flexible cable, its performance between YQ and YC, can withstand a certain external mechanical force; YC cable is a heavy rubber sheath flexible cable, its rubber layer is thicker, can withstand greater mechanical external force, more suitable for use in harsh environments. 

Q: What are their respective application scenarios? 

A: YQ cables are often used for low-power, high-flexibility equipment, such as small desk lamps and other small mobile electrical power lines. YZ cable is suitable for connecting cables of some power tools with moderate power, such as electric drills. YC cable is mainly used in large, need to move frequently and the working environment is harsh equipment, such as high-power power tools on construction sites, mining machinery and other power supply connection cables. 

Q: How do you distinguish between these three types of cables? 

A: It can be distinguished from the appearance, thickness and identification of the cable. In general, YC cable is the thickest, YZ is second, and YQ is the thinnest. And there is usually a clear sign on the cable indicating its model number.

Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放