• 110kV Porcelain housed Surge Arrester
110kV Porcelain housed Surge Arrester
discuss personally
Model
Y10WZ-300/727
HY10WZ-200/520
HY10WZ-100/260
HY5WS-10/30
Basic info
Brand Wone
Model NO. 110kV Porcelain housed Surge Arrester
Rated voltage 300kV
Continuous operating voltage 228kV
Lightning impulse residual voltage 727kV
Series Surge Arrester
Product Detail

Product introduction:

  • Surge arrester is also called overvoltage protector. It is connected in parallel with the protected electrical equipment. It can limit various overvoltage on electrical equipment, such as lightning overvoltage, operating overvoltage, etc., so as to protect the high voltage electrical from the damage of overvoltage.

  • Metaloxide varistor is used as the core component of surge arrester. The conductive mechanism of MOV is based on the non-linear volt-ampere characteristics of Schottky barrier model. The arrester is based on the principle of the non-linear volt-ampere characteristic of metal oxide varistor, which makes the arrester hold high resistance under the normal operating voltage of power system, which is equivalent to an insulator, and will not interfere with the normal operation of power system. When the overvoltage of power system endangers the safe operation of the system, the varistor triggers instantaneously and presents a low resistance. Forming a channel to release overvoltage energy, and clamp system voltage within the allowable range of the system to ensure the safe operation of the power system.

  • The arrester is porcelain-housed surge arrester. It has the advantages of high current impulse withstand capacity, large protection capacity and strong pollution resistance.

Parameter:

企业微信截图_17341409149808.png

 What are the structural characteristics of the porcelain shell arrester?

Porcelain Housing

The porcelain housing is a critical external structural component, offering excellent insulation properties and mechanical strength. The porcelain material can withstand electric field intensities of up to 110kV, preventing flashovers between internal components and the external environment. Additionally, the porcelain housing can endure certain mechanical stresses, such as wind and vibrations, protecting the sensitive internal components. Typically cylindrical in shape with a smooth surface, the porcelain housing helps reduce the adhesion of dust and contaminants. During manufacturing, it undergoes rigorous quality inspections to ensure there are no cracks or defects that could compromise its insulating properties.

Internal Components

The core internal component is the zinc oxide varistor disc. Under normal operating voltage, the zinc oxide varistor disc exhibits a high-resistance state, allowing only minimal current to pass through. When overvoltage occurs, its resistance drops sharply, forming a low-resistance path that allows the overvoltage-induced current to pass smoothly. These discs are made primarily from zinc oxide using specialized manufacturing processes, resulting in nonlinear volt-ampere characteristics that effectively limit the amplitude of overvoltages. Additionally, the internal structure may include connecting elements to link the varistor discs appropriately and auxiliary components like grading rings to ensure uniform voltage distribution across the discs during high-voltage conditions.

Sealing and Connection Structure

The porcelain-housed surge arrester features a robust sealing structure to prevent moisture, dust, and harmful gases from entering and affecting the performance of internal components. At both ends, there are connection structures for integrating the arrester into 110kV power lines. These connection parts are typically made of metal, capable of withstanding high voltages and large currents while providing excellent conductivity. This ensures that during an overvoltage event, current can flow smoothly into and out of the arrester.

Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放