• 40.5kV 72.5kV 126kV 252kV 363kV 500kV 800kV HV Grounding Switch
40.5kV 72.5kV 126kV 252kV 363kV 500kV 800kV HV Grounding Switch
discuss personally
Model
JW8-800-63
JW8-550-63
JW8-363-63
JW6-252-50
JW6-126-40
JW6-72.5-40
JW6-40.5-40
Basic info
Brand ROCKWILL
Model NO. JW6(8) Series HV Grounding Switch
Rated voltage 800kV
Series JW6(8) Series
Product Detail

Description

The JW6/8 series high-voltage grounding switches feature a three-single-pole configuration integrated with an operating mechanism. Each single pole comprises a base, a pillar insulator, and a conductive rod: the rod is mounted on the base, while the static contact is positioned at the top of the insulator.

Driven by the operating mechanism, the conductive rod rotates upward from the horizontal position via transmission components, latching or inserting into the static contact to achieve switch closure; the opening process reverses this motion.

Main Features:


  • Streamlined Design & Versatility:The product’s simple, rational structure enables effortless assembly, transportation, installation, and debugging, adapting to diverse field requirements.

  • High-Performance Conductive Components:Constructed from high-strength alloy profiles, the conductive rods offer excellent electrical conductivity, robust mechanical strength, and lightweight design. Their superior anti-corrosion properties ensure prolonged service life in harsh environments.

Technical parameter:

1732242955389.png

How is the indoor high-voltage AC grounding switch electrically tested?

  • Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance of the grounding switch. The insulation resistance value should meet the product standards and relevant electrical codes. Generally, for indoor high-voltage AC grounding switches, the insulation resistance should be in the range of several gigohms or more to ensure good insulation performance during operation and prevent leakage accidents.

  • Loop Resistance Test: Measure the loop resistance of the grounding switch using a dedicated loop resistance tester to check if the contact points are in good condition. The loop resistance value should fall within the specified range. If the loop resistance is too high, it may cause significant heating when current flows through the grounding switch, affecting its normal operation.

  • Grounding Performance Check: Ensure that the grounding connection is reliable and that the grounding resistance meets the requirements. If the grounding resistance is too high, it may prevent the current from being effectively discharged to the ground during a fault, thus failing to provide adequate protection for maintenance personnel and equipment.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Knowledges
Research on Power Quality Issues and Control Technologies at Distribution Transformer Terminals in PV Charging Stations
Research on Power Quality Issues and Control Technologies at Distribution Transformer Terminals in PV Charging Stations
1. IntroductionAs a frontline designer of photovoltaic charging station distribution systems, I deeply engage in power quality control technology research. Amid energy transition, photovoltaic charging stations grow in importance, yet large - scale PV integration brings power quality challenges. The distribution transformer end, a key node, urgently needs solutions. Despite existing research, gaps remain in control tech considering PV characteristics and complex conditions. This paper focuses on
Dyson
06/24/2025
Fault Diagnosis Analysis for Pad-Mounted Transformers in PV Power Plants
Fault Diagnosis Analysis for Pad-Mounted Transformers in PV Power Plants
As a front - line fault diagnosis and detection worker, I am well aware that with the expansion of the scale of photovoltaic power stations, the faults of box - type transformers, as one of the key equipment, have a profound impact on the stable operation of the system. This paper focuses on using advanced artificial intelligence algorithms and integrating data analysis technology to improve the accuracy and efficiency of fault diagnosis of box - type transformers, and to build a solid technical
Oliver Watts
06/24/2025
What is the operation mode of the step-up transformer in photovoltaic power generation?
What is the operation mode of the step-up transformer in photovoltaic power generation?
1 Overview of Photovoltaic Power Generation ProcessIn my daily work as a frontline operation and maintenance technician, the photovoltaic power generation process I encounter involves connecting individual solar panels into photovoltaic modules, which are then paralleled through combiner boxes to form a photovoltaic array. Solar energy is converted into direct current (DC) by the photovoltaic array, then transformed into three-phase alternating current (AC) via a three-phase inverter (DC-AC). Su
Echo
06/24/2025
Field Testing Procedures for Electric Vehicle Charging Piles
Field Testing Procedures for Electric Vehicle Charging Piles
As a technician deeply involved in charging pile testing on the frontline, my daily work makes one thing crystal clear: as people’s living standards rise, the demand for vehicles surges. Coupled with the growing popularity of environmental protection concepts, the electric vehicle (EV) industry is booming. Charging piles, as the “lifeline” of electric vehicles, directly determine whether EVs can operate stably and safely. Put simply, our job in testing is to “diagnose&rdq
Oliver Watts
06/24/2025
Design and Application of Smart EV Charging Piles
Design and Application of Smart EV Charging Piles
As a charging pile designer deeply involved in industry projects, I've witnessed firsthand how electric vehicles (EVs) have become a pivotal force in China's new energy landscape. Decades of advancements in electronics have laid a solid foundation for EV development. The integration of V2G, energy storage technologies, and high-performance batteries not only facilitates battery swapping services but also drives the convergence of photovoltaics, energy storage, and intelligent charging systems&md
Echo
06/24/2025
Electric Vehicle Charging Pile Testing Technologies and Failure Analysis
Electric Vehicle Charging Pile Testing Technologies and Failure Analysis
1. Detection Technology for Electric Vehicle Charging PilesEV charging piles are primarily divided into two categories:DC charging pilesandAC charging piles. Let's start with DC charging piles: they communicate with the EV's battery management system (BMS) and directly charge the power battery through the DC charging interface. AC charging piles, on the other hand, rely on the EV's AC charging interface and use the vehicle-mounted charger to complete the charging process. These two types of char
Oliver Watts
06/23/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!