• JN15-12 Series Indoor HV Earthing Switch
  • JN15-12 Series Indoor HV Earthing Switch
JN15-12 Series Indoor HV Earthing Switch
$1000.00
Model
JN15-12
Basic info
Brand Wone
Model NO. JN15-12 indoor high-voltage AC grounding switch
Rated voltage 12kV
Rated short circuit breaking current 80KA
Phase distance 210mm
Series JN15-12 Series
Product Detail

Description:

The grounding switch refers to a mechanical earthing device that releases the electrostatic charge of the equipment to be repaired and the circuit and ensures the personal safety of the maintenance personnel during power failure. It can withstand a certain period of time under abnormal conditions such as a short circuit, but does not pass through the load current under normal conditions. It is usually part of the disconnector.

Industry applications:

It is suitable for power systems with AC 50Hz of 12kV and below. It can be used for grounding protection during the maintenance of high-voltage electrical equipment, and can also be used with various types of high-voltage switchgear.

Features:

  • Ambient temperature: -15°C~+40°C.

  • Altitude: 1000m and below.

  • Relative humidity: daily average not more than 95%, monthly average not more than 90%.

  • The daily average value of water vapor pressure is not more than 2.2 kPa.

  • The monthly average water vapor pressure is not more than 1.8 kPa.

  • There is no fire, explosion hazard, serious pollution, chemical corrosion and severe vibration.

  • Our company has developed products suitable for high altitude (E≥230mm, altitude up to 4000m) for users to choose.

Technical parameters:

Serial 

number

Name Unit Data
1
Rated voltage KV
12
2 Rated short-time withstand current KA
31.5 40
3 Rated short-circuit duration S
4
2
4 Rated peak withstand current KA
80  100
5 Rated short-circuit 3-off current KA 80
100
6 Center distance between phases mm 150、210、275
7
1min power frequency withstand voltage (RMS) KV
42
Lightning impulse withstand voltage (peak) 75

Dimension:

image.png


Product show:

企业微信截图_17159945545177.png

企业微信截图_17159946028743.png

企业微信截图_17159946981926.png

Why choose us:

  • We have a professional service team

  • We have good after-sales

  • We can guarantee the quality of our products

What are the structural characteristics of indoor high-voltage AC grounding switch?

Contact System:

  • Materials: The contact system typically uses high-performance conductive materials such as copper alloys to ensure good conductivity and the ability to withstand high current impacts.

  • Design: The shape of the contacts can vary, including knife-type contacts and finger-type contacts, among others. These designs aim to increase the contact area, reduce contact resistance, and minimize heat generation.

Operating Mechanism:

  • Manual: Simple and reliable, with lower costs. Suitable for applications where the frequency of operation is low.

  • Electric: Enables remote control and automated operations, making it easy to integrate with the monitoring systems of substations.

  • Spring-Operated: Combines the advantages of manual and electric mechanisms. It uses pre-stored spring energy to achieve fast and reliable opening and closing operations.

Insulation Section:

  • Insulators: Primarily composed of insulators made from materials such as ceramic, glass, or composite materials.

  • Ceramic Insulators: High mechanical strength and excellent insulation properties.

  • Glass Insulators: Good self-cleaning performance, capable of resisting windblown sand and dirt to some extent.

  • Composite Material Insulators: Combine multiple advantages, such as being lightweight and having excellent pollution resistance.




Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放