• JDZW3-36 outdoor epoxy resin casting  Voltage  transformer
JDZW3-36 outdoor epoxy resin casting Voltage transformer
discuss personally
Model
JDZW3-36
Basic info
Brand Wone Store
Model NO. JDZW3-36 outdoor epoxy resin casting Voltage transformer
Rated frequency 50/60Hz
Primary voltage 35kV
Secondary voltage 110V
Series JDZW
Product Detail

Product Overview

JDZW3-36 voltage transformer, outdoor epoxy resin casting and double pole insulated VT, is widely used for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50Hz or 60Hz and insulation voltage 36 kV (Up to 40.5kV).

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Excellent Outdoor Insulation Protection:JDZW3-36 uses high-quality epoxy resin as the main insulation material, with a silicone rubber coating on the outer layer. The internal traditional epoxy resin casting process ensures the transformer's insulation and electrical performance. Silicone rubber features excellent arc resistance, hydrophobicity, and climatic adaptability, enabling the equipment to operate normally in high-altitude, high-salt fog, rainy, and strong UV environments. Even if system faults cause explosions, the external silicone rubber structure restrains internal resin, reducing splashing damage to surrounding personnel, livestock, or equipment.
  • High Precision & Low Partial Discharge:The vacuum casting process achieves uniform electric field distribution with low partial discharge, enabling precise voltage measurement. Voltage ratio error is controlled within a minimal range, meeting high-precision metering and protection needs to provide reliable voltage data for 36kV and below power systems.
  • Fully Enclosed & Sealed Design:Primary and secondary terminals are completely sealed to prevent dust, moisture, and impurities from invading, avoiding electrical performance degradation caused by external factors. This extends service life and ensures stable operation in complex outdoor environments.
  • Strong Anti-Fouling Capability:The external insulation has high dry arc and large creepage distance, with creepage distance meeting or exceeding relevant standards—especially suitable for high-pollution areas. The surface undergoes special treatment to further enhance anti-fouling performance and reduce flashover risks.
  • Durable Metal Components:All metal components are hot-dip galvanized to enhance corrosion resistance, withstanding long-term outdoor exposure to wind, rain, and sunlight—ensuring reliable long-term service in outdoor environments.

Main technical parameter

  • Rated primary voltage:30 kV or 33 kV or 35 kV etc.
  • Rated secondary voltage:100 V or 110 V
  • Rated power-frequency withstand voltage: 70kV
  • Rated lightning impulse withstand voltage: 170kV
  • Technical standard accords with IEC 60044-2.2003.
  • Other parameters pls see as follow:

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Switchgear parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What should be noted when selecting and installing GIS voltage transformers?
What should be noted when selecting and installing GIS voltage transformers?
In power systems, voltage transformers in GIS (Gas Insulated Switchgear) play a crucial role in voltage measurement and relay protection. Selecting the right model and installing it correctly is vital for the stable operation of the equipment. The following points should be noted regarding selection and installation.I. Key Points for Selection(1) Matching Rated ParametersVoltage Level: It must be consistent with the voltage level of the GIS system. For example, 110kV and 220kV GIS systems requir
James
07/08/2025
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
1. Accident Overview1.1 Structure and Connection of 35kV GIS Switchgear Voltage TransformerThe ZX2 gas-insulated double-bus switchgear, manufactured in March 2011 and officially put into operation in July 2012, is configured with two groups of bus voltage transformers (PTs) for each bus section. The two PT groups of the same bus section are designed in one switchgear cabinet with a width of 600 mm. The three-phase PTs are arranged in a triangular formation at the bottom of the cabinet.The PTs ar
Felix Spark
07/08/2025
What Are the Steps for Error Testing GIS Voltage Transformers?
What Are the Steps for Error Testing GIS Voltage Transformers?
Hey everyone, I'm Oliver, and I've been working with current transformers (CTs) and voltage transformers (VTs) for 8 years.From assisting my mentor on site to leading high-voltage testing teams and conducting error calibrations independently, I’ve dealt with all kinds of instrument transformers — especially those used in GIS systems. The error test for voltage transformers is something I perform regularly.A few days ago, a friend asked me:“Oliver, how exactly do you perform an
Oliver Watts
07/08/2025
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
1. Accident OverviewA newly - built 110kV substation’s GIS exploded during commissioning due to a PT secondary circuit short - circuit. Though the cause was simple, consequences were severe, warranting reflection.2. Accident ProcessOn the power - transmission day:The upper - level power supply charged the 110kV GIS (a combined appliance).20s after closing the incoming switch and first live - impacting the 110kV bus, white smoke emerged between the PT compartment and control cabinet.Within
Felix Spark
07/08/2025
Operation Method for PT Resonance in 500kV GIS Switching Station
Operation Method for PT Resonance in 500kV GIS Switching Station
1. Causes of ResonanceA 500kV GIS switching station is designed following the principle of “primary equipment intelligence and secondary equipment networking”. The PT high - voltage side has no disconnector and is directly connected to the bus GIS. Through the analysis of fault recording diagrams, when the 5021 circuit breaker opens, the fracture capacitance and PT form a series circuit. Moreover, the bus voltage, after being paralleled by the PT inductance, shows inductive character
James
07/08/2025
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!