• 12kV Indoor High Voltage Vacuum Circuit Breaker
  • 12kV Indoor High Voltage Vacuum Circuit Breaker
  • 12kV Indoor High Voltage Vacuum Circuit Breaker
12kV Indoor High Voltage Vacuum Circuit Breaker
discuss personally
Model
VDS4-12-3150
VDS4-12-2500
VDS4-12-2000
VDS4-12-1600
VDS4-12-1250
VDS4-12-630
Basic info
Brand ROCKWILL
Model NO. 12kV Indoor High Voltage Vacuum Circuit Breaker
Rated voltage 12kV
Rated normal current 3150A
Series VDS4
Product Detail

Product Introduction

The VDS4 series indoor high-voltage AC vacuum circuit breaker is designed for three-phase AC 50Hz power systems with a rated voltage ranging from 7.2 to 40.5kV. Widely applied in substations, power plants, industrial facilities, airports, and buildings, it excels at controlling and safeguarding electrical equipment. With its capabilities for frequent operations and rapid reclosing, it ensures reliable power management.

This breaker adheres to national standards, including GB/T 1984-2014 "High Voltage AC Circuit Breaker", JB/T 3855-2008 "High Voltage AC Vacuum Circuit Breaker", and DL/T 403-2000 "12kV~40.5kV Indoor AC High Voltage Vacuum Circuit Breaker Ordering Technical Requirements". It also complies with international regulations set by the International Electrotechnical Commission, such as IEC 62271-100, IEC 60694, and IEC 62271-1, guaranteeing quality and global compatibility.

Technical parameters

The following table details the key technical specifications of the product, comprehensively covering electrical performance, mechanical characteristics, and dimensional parameters to provide a clear reference for technical selection and application scenarios.

Features
The product offers multiple significant advantages, which can fully meet the diverse needs of industrial and power systems. Specifically included are:

  •  Excellent Electrical Performance of Fully Enclosed Pole

The main circuit of the VSV series vacuum circuit breaker adopts a fully enclosed structure, available in two types: insulated cylinder or solid pole.

  • Insulated Cylinder Structure:

The main electrical components are longitudinally installed in an epoxy resin cylinder cast via the APG process. This structure offers superior arc resistance, anti-aging properties, and high mechanical strength. It effectively shields the vacuum interrupter from external factors such as mechanical impacts and environmental pollution while enhancing the conductive circuit’s capability to withstand rated short-term (peak) withstand currents.

  • Sealed Pole Structure (P Series):

The miniaturized vacuum interrupter and other main circuit components are directly sealed in epoxy resin using advanced APG technology. This not only simplifies the pole assembly process and improves the reliability of the vacuum interrupter’s conductive circuit but also protects the interrupter’s outdoor surface from external mechanical forces and environmental influences.

  •  Corrosion-Resistant Mechanism with Advanced Design

Structural components undergo super anti-corrosion and anti-salt spray zinc-nickel alloy treatment.

Transmission parts are treated with high-hardness, wear-resistant, and corrosion-resistant nickel-phosphorus alloy.

International brand INA oil-free graphite bearings are used for transmission, ensuring high strength and excellent wear resistance.

  •  C2-Level Circuit Breaker Compliance

During capacitive current interruption, the breaker exhibits an extremely low probability of re-strike, fully meeting the requirements for C2-level circuit breakers.

  •  E2-Level Circuit Breaker Certification

The breaker has successfully passed all tests at the Shenyang High Voltage Electrical Appliance Research Institute and Xi’an High Voltage Electrical Appliance Research Institute testing centers. It complies with the E2-level standard, demonstrating:

  • 30 operations with full-rated short-circuit current for low-current breakers.

  • 20 operations with full-rated short-circuit current for high-current breakers.

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
Analysis of the Technical Characteristics of Online Monitoring for Medium-Voltage Switchgear Status
Analysis of the Technical Characteristics of Online Monitoring for Medium-Voltage Switchgear Status
With the increasing complexity of power system operation environment and the deepening of power system reform, traditional power grids are accelerating the transformation to smart grids. The goal of equipment condition-based maintenance is achieved through real-time perception of equipment status by new sensors, reliable communication via modern network technology, and effective monitoring by background expert systems.I. Analysis of Condition-based Maintenance StrategyCondition-based Maintenance