• 36KV SF6 Load Break Switch
36KV SF6 Load Break Switch
discuss personally
Model
RLS-36
Basic info
Brand ROCKWILL
Model NO. 36KV SF6 Load Break Switch
Rated voltage 36kV
Series RLS
Product Detail

Product Overview

The RLS-36 is a 36kV/40.5kV SF6 gas-insulated load break switch designed for indoor medium-voltage applications. Utilizing SF6 gas for superior arc quenching and insulation, it features a three-position switching mechanism (ON-OFF-GROUND) in a compact, space-saving design. The RLS-36 and its fused combination variant provide reliable protection and control for power distribution networks, particularly in ring main units (RMUs), cable branch cabinets, and distribution substations.

Compliant with GB3804-1990, IEC60256-1:1997, GB16926, and IEC60420, this switchgear ensures safe and efficient operation in diverse electrical environments.

 

Key Features

  • SF6 Gas Insulation– Superior arc extinction and dielectric strength

  • Three-Position Switching– Make, break, and ground functions in one unit

  • Compact Design– Space-efficient for easy installation in confined spaces

  • Fused Combination Option– Enhanced protection for transformers and cables

  • High Adaptability– Reliable performance in harsh environments

 

Product Advantages

  • Enhanced Safety– SF6 gas prevents arc flashes and ensures stable operation

  • Low Maintenance– Sealed design reduces maintenance requirements

  • Flexible Configuration– Standard or fused versions available

  • Wide Compliance– Meets GB, IEC, and international standards

  • Robust Construction– Withstands high humidity (95%) and altitude (2500m)

 

Application Scenarios

  • Ring Main Units (RMUs)– Secure load switching in urban power grids

  • Cable Branch Cabinets– Reliable power distribution for industrial zones

  • Distribution Substations– Safe load control in medium-voltage networks

  • Transformer Protection– Fused version prevents fault escalation

 

Environmental Specifications

  • Operating Temperature: -5°C to +40°C

  • Humidity Tolerance: Daily avg. 90% / Monthly avg. 95%

  • Max. Altitude: 2500m

Technical data

Matching dimension of SF6 load break switch-fuse combination

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What should be noted when selecting and installing GIS voltage transformers?
What should be noted when selecting and installing GIS voltage transformers?
In power systems, voltage transformers in GIS (Gas Insulated Switchgear) play a crucial role in voltage measurement and relay protection. Selecting the right model and installing it correctly is vital for the stable operation of the equipment. The following points should be noted regarding selection and installation.I. Key Points for Selection(1) Matching Rated ParametersVoltage Level: It must be consistent with the voltage level of the GIS system. For example, 110kV and 220kV GIS systems requir
James
07/08/2025
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
1. Accident Overview1.1 Structure and Connection of 35kV GIS Switchgear Voltage TransformerThe ZX2 gas-insulated double-bus switchgear, manufactured in March 2011 and officially put into operation in July 2012, is configured with two groups of bus voltage transformers (PTs) for each bus section. The two PT groups of the same bus section are designed in one switchgear cabinet with a width of 600 mm. The three-phase PTs are arranged in a triangular formation at the bottom of the cabinet.The PTs ar
Felix Spark
07/08/2025
What Are the Steps for Error Testing GIS Voltage Transformers?
What Are the Steps for Error Testing GIS Voltage Transformers?
Hey everyone, I'm Oliver, and I've been working with current transformers (CTs) and voltage transformers (VTs) for 8 years.From assisting my mentor on site to leading high-voltage testing teams and conducting error calibrations independently, I’ve dealt with all kinds of instrument transformers — especially those used in GIS systems. The error test for voltage transformers is something I perform regularly.A few days ago, a friend asked me:“Oliver, how exactly do you perform an
Oliver Watts
07/08/2025
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
1. Accident OverviewA newly - built 110kV substation’s GIS exploded during commissioning due to a PT secondary circuit short - circuit. Though the cause was simple, consequences were severe, warranting reflection.2. Accident ProcessOn the power - transmission day:The upper - level power supply charged the 110kV GIS (a combined appliance).20s after closing the incoming switch and first live - impacting the 110kV bus, white smoke emerged between the PT compartment and control cabinet.Within
Felix Spark
07/08/2025
Operation Method for PT Resonance in 500kV GIS Switching Station
Operation Method for PT Resonance in 500kV GIS Switching Station
1. Causes of ResonanceA 500kV GIS switching station is designed following the principle of “primary equipment intelligence and secondary equipment networking”. The PT high - voltage side has no disconnector and is directly connected to the bus GIS. Through the analysis of fault recording diagrams, when the 5021 circuit breaker opens, the fracture capacitance and PT form a series circuit. Moreover, the bus voltage, after being paralleled by the PT inductance, shows inductive character
James
07/08/2025
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!