• 45-12000 kVA Three-phase pad-mounted transformers
45-12000 kVA Three-phase pad-mounted transformers
discuss personally
Model
ZGS-46
Basic info
Brand Vziman
Model NO. 45-12000 kVA Three-phase pad-mounted transformers
Rated frequency 50/60Hz
Primary voltage 2400V-46000V
Secondary voltage 120V-24940V
Capacity range 45kVA-12000kVA
Series ZGS
Product Detail

Descripton:

Three-phase pad-mounted transformers (ANSI )are sustainable, high-performance, and safety-first power solutions. Filled with FR3 environmentally friendly insulating fluid, they possess excellent flame-retardant properties. Their insulation system lifespan is 5 to 8 times longer than that of traditional mineral oil transformers, significantly extending the service cycle of the equipment, effectively reducing the replacement frequency, and achieving long-term and stable asset value.

Features:

  • Fire Safety Assurance:Build an unbreakable fire safety defense line, always maintaining an unparalleled record of zero fire accidents, and setting an industry benchmark for the safety of power operation.

  • Equipment Lifespan Advantage:Its outstanding durability far exceeds that of similar products. The service life of the equipment is three times that of traditional mineral oil transformers, greatly reducing replacement and maintenance costs and maximizing asset value.

  • Characteristics of Environmentally Friendly Oil:Adopt environmentally friendly transformer oil with a high flash point. It is not only easily biodegradable but also completely non-toxic and harmless. While ensuring stable power transmission, it minimizes the impact on the ecological environment.

  • Economic and Environmental Performance:The FR3 fluorinated fluid continuously delivers efficient and stable performance at an affordable cost, perfectly balancing economic efficiency and sustainability, and contributing to the construction of a green power ecosystem.

  • Standard Compliance:The fluid used strictly adheres to the dual stringent standards of ASTM D6871-03 and IEEE PC57.147, ensuring the reliability of product quality and performance from the source.

  • Customized Design:The innovative compartmentalized transformer adopts a highly flexible customized design concept, which can accurately meet the diverse needs and personalized specifications of customers and provide exclusive power solutions.

Technical Parameters:

Ratings:

Standards:

Enclosure:

Key features:

 

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download